에 의해 게시 BITZER SE
1. These include, for example, GWP and ODP values for the refrigerants, safety group, chemical composition or components in mixtures, CAS number, molecular weight, triple and boiling (bubble) points, critical temperature, critical pressure and information on the type of oil for the compressor.
2. ▸ Ruler: By means of a slider, the values of pressure, dew and boiling (bubble) temperatures (temperature glide resulting from the difference) for the selected refrigerant can be determined.
3. With this setting, the atmospheric pressure can be entered either manually on the upper ruler or via the "barometer symbol" to correct the pressure values.
4. ▸ Automatic Barometer: The app offers the possibility to determine the current altitude above sea level and/or the actual atmospheric pressure to correct the corresponding dew and bubble temperatures in case of overpressure settings.
5. Pressure and temperature values can also be entered manually - either by tapping on the respective field or via the symbol "123".
6. A change to absolute pressure values is possible under "Settings", the atmospheric pressure correction is then inactive.
7. ▸ Settings: Under this menu all important parameters for the determination of the atmospheric pressure as well as for temperature and pressure values can be adjusted.
8. ▸ Search filters and favourites: Under the navigation item "Search" or via predetermined "Search filters" or manual entry in the text field the appropriate refrigerant can be found and, if necessary, added to the favourites by tapping the "star symbol".
9. In the Setting psig / inHg displays the overpressure values in "psig" and the negative pressure values in "negative inHg" (e.g., -7.5 inHg).
10. The app contains all common refrigerants, including key fluid properties, safety group information, global warming potential (GWP), ozone depletion potential (ODP), and information on choice of oil type for the compressor.
11. ▸ The app contains data and information on more than 100 natural and synthetic refrigerants, which can also be preselected by filter functions (under "Search").
또는 아래 가이드를 따라 PC에서 사용하십시오. :
PC 버전 선택:
소프트웨어 설치 요구 사항:
직접 다운로드 가능합니다. 아래 다운로드 :
설치 한 에뮬레이터 애플리케이션을 열고 검색 창을 찾으십시오. 일단 찾았 으면 BITZER REFRIGERANT RULER 검색 막대에서 검색을 누릅니다. 클릭 BITZER REFRIGERANT RULER응용 프로그램 아이콘. 의 창 BITZER REFRIGERANT RULER Play 스토어 또는 앱 스토어의 스토어가 열리면 에뮬레이터 애플리케이션에 스토어가 표시됩니다. Install 버튼을 누르면 iPhone 또는 Android 기기 에서처럼 애플리케이션이 다운로드되기 시작합니다. 이제 우리는 모두 끝났습니다.
"모든 앱 "아이콘이 표시됩니다.
클릭하면 설치된 모든 응용 프로그램이 포함 된 페이지로 이동합니다.
당신은 아이콘을 클릭하십시오. 그것을 클릭하고 응용 프로그램 사용을 시작하십시오.
다운로드 BITZER REFRIGERANT RULER Mac OS의 경우 (Apple)
다운로드 | 개발자 | 리뷰 | 평점 |
---|---|---|---|
Free Mac OS의 경우 | BITZER SE | 1004 | 4.65 |
The BITZER REFRIGERANT RULER enables easy and fast determination of refrigerant data. The app contains all common refrigerants, including key fluid properties, safety group information, global warming potential (GWP), ozone depletion potential (ODP), and information on choice of oil type for the compressor. Furthermore, additional information on refrigerants, links to relevant online documents and other information are displayed (under "More..." in the menu bar). The tool provides an intuitive user interface for easy and accurate temperature-to-pressure conversion, while allowing easy use and switching between different metric (SI) and imperial (IP) units (under "Settings"). // CURRENTLY AVAILABLE REFRIGERANTS // ▸ The app contains data and information on more than 100 natural and synthetic refrigerants, which can also be preselected by filter functions (under "Search"). ▸ For comparison purposes and also for practical use in service and operation of older existing systems, information on previously used refrigerants, which may have been affected by usage restrictions, are also provided. // MAIN FUNCTIONS // ▸ Search filters and favourites: Under the navigation item "Search" or via predetermined "Search filters" or manual entry in the text field the appropriate refrigerant can be found and, if necessary, added to the favourites by tapping the "star symbol". With a simple touch on the selected refrigerant, the slider for the pressure-temperature conversion is displayed. ▸ Ruler: By means of a slider, the values of pressure, dew and boiling (bubble) temperatures (temperature glide resulting from the difference) for the selected refrigerant can be determined. Pressure and temperature values can also be entered manually - either by tapping on the respective field or via the symbol "123". When installing the app overpressure values are preset. With this setting, the atmospheric pressure can be entered either manually on the upper ruler or via the "barometer symbol" to correct the pressure values. A change to absolute pressure values is possible under "Settings", the atmospheric pressure correction is then inactive. Further function: By tapping on the refrigerant name, direct access to "Search" (refrigerant list and search filters) is also possible. ▸ Settings: Under this menu all important parameters for the determination of the atmospheric pressure as well as for temperature and pressure values can be adjusted. Other functions allow for a change to default settings and a repeated display of the “Tutorials” in the ruler view. ▸ Automatic Barometer: The app offers the possibility to determine the current altitude above sea level and/or the actual atmospheric pressure to correct the corresponding dew and bubble temperatures in case of overpressure settings. Depending on the configuration, the analysis for the location in question is optionally carried out automatically via GPS or barometer if the corresponding terminal has the aforementioned sensors. Manually entering the atmospheric pressure or correction is possible as described under “Slider control”. ▸ Temperature / pressure: Temperature and pressure units can be freely selected and combined, if necessary, a mix of SI and IP units is possible as well. For overpressure (or negative pressure) bar (g) or psig / inHg can be selected. In the Setting psig / inHg displays the overpressure values in "psig" and the negative pressure values in "negative inHg" (e.g., -7.5 inHg). ▸ Further information on refrigerants: General and additional information can be found under the information symbol "i" in the header next to the refrigerant name. These include, for example, GWP and ODP values for the refrigerants, safety group, chemical composition or components in mixtures, CAS number, molecular weight, triple and boiling (bubble) points, critical temperature, critical pressure and information on the type of oil for the compressor.
네이버 - NAVER
네이버 파파고 - AI 통번역
Google 번역
다음 - Daum
OP.GG - 오피지지
색상환
공동체 성경 읽기(드라마바이블)
네이트 (nate)
성경 (Bible)
작명어플 : 넴유베 (Name Your Baby)
나이트 스카이
Stats Royale for Clash Royale
영한사전 - Dict Box
MBTI 성격유형 소개
Telegram 그룹