1. This app will provide SMACNA compliant options for rectangular duct with dimensions from 1 inch to 120 inches for applications from negative to positive ten inch water gage.
2. In most cases the app will provide options for internal reinforcements and external reinforcements.
3. Internal options are limited to EMT conduit tie rods and external reinforcements are limited to angles.
4. The app does not provide every possible solution found in SMACNA’s standard and it will not provide every detail.
5. Enough information is provided so users can choose other options from SMACNA’s Standard.
6. Where appropriate the app will also provide options for intermediate reinforcement.
7. For example, the app does not provide requirements for the proper attachment of the reinforcements.
8. The transverse connections are limited to T1 (flat drive), T5 (flat slip), T10, 11, and 12 (standing slips) and T25 a or b (TDC/TDF).
9. The full range of reinforcement spacing options is 6, 5, 4, 3, 2 ½, and 2 feet.
10. The app is intended to be used in conjunction with SMACNA’s HVAC Duct Construction Standard.
11. The scenarios for the app are limited to joint lengths of 4, 5, and 6 feet.
또는 아래 가이드를 따라 PC에서 사용하십시오. :
PC 버전 선택:
소프트웨어 설치 요구 사항:
직접 다운로드 가능합니다. 아래 다운로드 :
설치 한 에뮬레이터 애플리케이션을 열고 검색 창을 찾으십시오. 일단 찾았 으면 SMACNA HVAC DCS 검색 막대에서 검색을 누릅니다. 클릭 SMACNA HVAC DCS응용 프로그램 아이콘. 의 창 SMACNA HVAC DCS Play 스토어 또는 앱 스토어의 스토어가 열리면 에뮬레이터 애플리케이션에 스토어가 표시됩니다. Install 버튼을 누르면 iPhone 또는 Android 기기 에서처럼 애플리케이션이 다운로드되기 시작합니다. 이제 우리는 모두 끝났습니다.
"모든 앱 "아이콘이 표시됩니다.
클릭하면 설치된 모든 응용 프로그램이 포함 된 페이지로 이동합니다.
당신은 아이콘을 클릭하십시오. 그것을 클릭하고 응용 프로그램 사용을 시작하십시오.
다운로드 SMACNA HVAC DCS Mac OS의 경우 (Apple)
다운로드 | 개발자 | 리뷰 | 평점 |
---|---|---|---|
$12.99 Mac OS의 경우 | SMACNA | 6 | 2.17 |
PC를 설정하고 Windows 11에서 SMACNA HVAC DCS 앱을 다운로드하는 단계:
This app will provide SMACNA compliant options for rectangular duct with dimensions from 1 inch to 120 inches for applications from negative to positive ten inch water gage. The scenarios for the app are limited to joint lengths of 4, 5, and 6 feet. The transverse connections are limited to T1 (flat drive), T5 (flat slip), T10, 11, and 12 (standing slips) and T25 a or b (TDC/TDF). Where appropriate the app will also provide options for intermediate reinforcement. The full range of reinforcement spacing options is 6, 5, 4, 3, 2 ½, and 2 feet. In most cases the app will provide options for internal reinforcements and external reinforcements. Internal options are limited to EMT conduit tie rods and external reinforcements are limited to angles. Enough information is provided so users can choose other options from SMACNA’s Standard. The output of the app is a written description of the duct as well as a graphic representation. Users can view the report on-screen or email it. The app does not provide every possible solution found in SMACNA’s standard and it will not provide every detail. For example, the app does not provide requirements for the proper attachment of the reinforcements. The app is intended to be used in conjunction with SMACNA’s HVAC Duct Construction Standard.