에 의해 게시 Nikolaos Papadimitriou
1. In Total hip Arthroplasty the orientation, namely anteversion and inclination of the new acetabular component -cup- influences wear, range of movement (ROM), and the likelihood of dislocation after total hip replacement (THR).
2. Nomura T, Naito M, et al .An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs.
3. -Radiographic Inclination (RI) and Radiographic Anteversion (RA) values are adjusted by taking into account pelvic tilt (APP angle).
4. -By marking certain anatomical landmark and points in a simple standard AP pelvic radiograph, values for cup inclination and anteversion are being calculated.
5. Evaluating objectively of the cup anteversion, and inclination in hip arthroplasty replacement surgery is of paramount importance.
6. In a busy THA practice, the examiner to draw lines in X-rays, it is time consuming and cumbersome to calculate mathematics.This App is particular useful in clinical settings where you need a quick results without losing time.
7. The app offers an easy way to quantify cup anteversion and inclination a quick and comfortable manner without the use of a goniometer or a ruler or to calculate elaborated formulas.
8. Measuring anteversion and inclination in everyday clinical setting is a cumbersome work for a medical doctor.
9. Widmer KH A simplified method to determine acetabular cup anteversion from plain radiographs.
10. - RI or RA values are printed in red or green, according to measured value in cases these are in certain range (Lewinnek at al), indicating if the positioning of the cup is optimal (green) or not (red).
11. Radiographs are the most important diagnostic means in the follow-up for evaluation of a total hip arthroplasty.
호환되는 PC 앱 또는 대안 확인
앱 | 다운로드 | 평점 | 개발자 |
---|---|---|---|
![]() |
앱 또는 대안 다운로드 ↲ | 0 1
|
Nikolaos Papadimitriou |
또는 아래 가이드를 따라 PC에서 사용하십시오. :
PC 버전 선택:
소프트웨어 설치 요구 사항:
직접 다운로드 가능합니다. 아래 다운로드 :
설치 한 에뮬레이터 애플리케이션을 열고 검색 창을 찾으십시오. 일단 찾았 으면 CupAnteversionInclinationApp 검색 막대에서 검색을 누릅니다. 클릭 CupAnteversionInclinationApp응용 프로그램 아이콘. 의 창 CupAnteversionInclinationApp Play 스토어 또는 앱 스토어의 스토어가 열리면 에뮬레이터 애플리케이션에 스토어가 표시됩니다. Install 버튼을 누르면 iPhone 또는 Android 기기 에서처럼 애플리케이션이 다운로드되기 시작합니다. 이제 우리는 모두 끝났습니다.
"모든 앱 "아이콘이 표시됩니다.
클릭하면 설치된 모든 응용 프로그램이 포함 된 페이지로 이동합니다.
당신은 아이콘을 클릭하십시오. 그것을 클릭하고 응용 프로그램 사용을 시작하십시오.
다운로드 CupAnteversionInclinationApp Mac OS의 경우 (Apple)
다운로드 | 개발자 | 리뷰 | 평점 |
---|---|---|---|
$33.99 Mac OS의 경우 | Nikolaos Papadimitriou | 0 | 1 |
In Total hip Arthroplasty the orientation, namely anteversion and inclination of the new acetabular component -cup- influences wear, range of movement (ROM), and the likelihood of dislocation after total hip replacement (THR). Evaluating objectively of the cup anteversion, and inclination in hip arthroplasty replacement surgery is of paramount importance. Radiographs are the most important diagnostic means in the follow-up for evaluation of a total hip arthroplasty. Measuring anteversion and inclination in everyday clinical setting is a cumbersome work for a medical doctor. Computation requires a calculator, which requires an additional effort during practice and slows down workflow. The App is medical software aimed for orthopaedic surgeons, providing a tool that allow doctors to: -Securely import medical images directly from the camera or stored photos. -By marking certain anatomical landmark and points in a simple standard AP pelvic radiograph, values for cup inclination and anteversion are being calculated. The app is based on Widmer’s method which is the proven that is the most accurate compared to others. -Pelvic tilt expressed by the angle APP is incorporated in measurements and can be adjusted manually according to surgeons preference. -Radiographic Inclination (RI) and Radiographic Anteversion (RA) values are adjusted by taking into account pelvic tilt (APP angle). - RI or RA values are printed in red or green, according to measured value in cases these are in certain range (Lewinnek at al), indicating if the positioning of the cup is optimal (green) or not (red). -The data are printed over to screen so each case can easily assessed. -For more accurate results the source of central ray of the x-ray should be at position at 1150mm away from x ray table . -Save the planned images, for later review or consultation. The app offers an easy way to quantify cup anteversion and inclination a quick and comfortable manner without the use of a goniometer or a ruler or to calculate elaborated formulas. All information received from the software output must be clinically reviewed regarding its plausibility before patient treatment! The App is indicated for assisting healthcare professionals. Clinical judgment and experience are required to properly use the software.The software is not for primary image interpretation. In a busy THA practice, the examiner to draw lines in X-rays, it is time consuming and cumbersome to calculate mathematics.This App is particular useful in clinical settings where you need a quick results without losing time. Please see tutorial videos at the developer’s web site www.orthopractis.com Reference 1. Nomura T, Naito M, et al .An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs. Bone Joint J. 2014 May;96-B(5):597-603. 2. Bachhal V, Jindal N, Saini G, Sament R, Kumar V, Chouhan D, Dhillon M. A new method of measuring acetabular cup antev- ersion on simulated radiographs. Int Orthop. 2012;36:1813–1818. 3. Widmer KH A simplified method to determine acetabular cup anteversion from plain radiographs. J Arthroplasty. 2004 Apr;19(3):387-90. 5. Murray DW: The definition and measurement of acetabular orientation. J Bone Joint Surg Br 1993 75:228, 6. Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220 7. Schwarz TJ et al. Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study. Rofo. 2017 Sep;189(9):864-873.
질병관리청 COOV(코로나19 전자예방접종증명서)
The건강보험
닥터나우 - 원격진료부터 약 배송까지
생활치료센터 비대면진료서비스
올라케어 - 아플땐 병원 바쁠땐 올라케어
바이코로나(Bye COVID-19)
마미톡 - 임신부터 출산, 육아까지
280days : 부부가 공유하는 "임신 기록/일기"
BabyTime (아기 육아 기록&분석, 베이비타임)
베이비빌리 - 태교, 임신, 출산, 육아 정보
세이베베 - 임신, 출산, 육아
열나요 - Fever Coach
서울대학교병원
메디피움
순산해요